Evaporative Cooling Unit - Reduce the temperature with low electric consumption

 

FUNCTIONING

 

The electric consumption is reduced, only needed for feeding a fan and a small pump of wather. What cools the environment is the process of evaporation of the water that removes heat of air, reducing the temperature of the ambient.

 

BENEFITS

HEALTH
Humid and filtered air
Total renewal of the air of the environment in 20 the 30 times per hour
Reduction of odors, smoke, bacteria, dust and virus

INCREASE IN PRODUCTIVITY
With more pleasant and healthful environment the productivity of the employees increases at the same time that reduces illness and accidents.

ECONOMY
90% less energy if compared with an air conditioner system

ECOLOGICAL
It does not use gases as CFC or HCFC (common in
air conditioner and harmful to the environment)
Low electric consumption

APPLICATIONS
Climatization of large areas like industrial plants and you would print or of areas with much circulation of people as store and super markets

 

 

     
  COMPARATIVE BETWEEN TEMPERATURE OF THE INTERNAL AND EXTERNAL ENVIRONMENT
 
Temperature of air in the entrance of the cooling unit Temperature of air in the exit of the coolinig unit

1) The temperature of the environment is between 3 to 5°C above of the temperature of air in the exit of the cooling unit, depending on the thermal load (heat sources).


2) The temperature in the exit of the cooling unit changes according to humidity of air. The more dry is the air, more the temperature is reduced by the cooling unit, that is, its performance is better in the hours of heat peak during the day that is between 11:00 and 16:00 h. The table to the side is referring to a relative humidity of 40%.
25°C 18°C
32°C 24°C
37°C 28,5°C
     
  MODELS OF EVAPORATIVE  COOLING UNITS
 
Model EB-80 EB-100 EB-150 EBV-25 ABS EBV-35 ABS EBV-42 ABS
Air outflow (m³ /h) 5.000 6.000 9.500 25.000 35.000 42.000
Electric consum. (w/h) 196 370 410 900 900 1.240
Dimensions (cm) (1) 93x93x63 117x95x76 122x126x80 174x127x89 175x156x127 182x158x127
Opening wall (cm) 43 x 82 68 x 88 87 x 87 92 x 92 121 x 121 121 x 121
Weight (kg) 60 60 75 120 150 165
Area (m ²) (2) 30 a 80 50 a 100 75 a 150 150 a 300 200 a 400 300 a 500
Water consum. (l/h) 8 10 15 35 45 65

(1) - the dimensions are height x width x depth

(2) - The climatized maximum area will go to depend on the sources of internal environment heat.

 

Comparative between EVAPORATIVE COOLINGx air conditioner x water fan x common fan

 

  EVAPORATIVE COOLING Air conditioner Water fan Coomon Fan
Investiment Medium High Low Very low
Energy consumption Low Very High Low Low
Requirements of
environment
Open environment. It has great air renewal
(next the 100%)
Closed environment. Not
it has air renewal

Work well in tall bullding and

smal areas

It does not have requirements
Effect in
temperature
It cools air in accordance with
the humidity of air
It cools air in accordance with
the regulation of
thermostat
It cools air in accordance with
relative humidity of air
It does not modify the temperature,
but it puts into motion air
hot
Effect in
humidity
It increases the humidity of air without reaching
saturation
It dries air It increases the humidity. In
more humid days it arrives
to wet the environment
It does not modify the humidity
Effect in
health
Excellent because it renews air. The umidification of air
is very good to health
Bad because it dries air and
it does not have renewal
The umidificação is one
benefit in climates
very dry
Useful in environments with
generation of heat or of
pollutants
Impacts in the
environment
No impact
negative
Negative impact for high
consumption of energy and use
of gas CFC and HCFC
No impact
negative
No impact
negative
Maintenance Low and simple High and specialized High (peaks obstructed
with frequency)
Very low
 
   
 